Sizes




CONFIGURATIONS
   - CyberShield™
   - Insulating
   - Laminated
   - Insulating Laminated
   - Laminated Insulating
   - Double Laminated Insulating
   - Monolithic
   - Triple Insulating

COMPONENTS
   - Coatings
   - Glass Substrates
   - Heat Treatment
   - Spacer
   - Silicone
   - Interlayer

ENHANCEMENTS
   - Argon
   - DigitalDistinctions™
   - Edgework
   - Holes
   - Notches
   - Silk-screen
   - Spandrel

PERFORMANCE
   - Solar
   - Acoustic

SIZES
   - BIG Glass

WARRANTIES

QUALITY

 

BIG GLASS CONFIGURATIONS AVAILABLE UP TO 130” X 236”.

Glass sizing is based on 1/4" (6mm) to 3/8" (10mm) thickness for both interior and exterior lites in vertical applications.

 

Monolithic Glass Sizes

Monlithic Sizes

70 sq ft

 

Configurations:

  • >50 square foot units must be heat treated.

 

Components & Enhancements:

  • Ceramic frit silk-screen or spandrel units cannot exceed 84” wide x 165" high.
  •  


 

Insulating Glass Sizes

 
70 sq ft
 

 

Configurations:

  • >50 square foot units must be heat treated.

 

Components & Enhancements:

  • Ceramic frit silk-screen or spandrel units cannot exceed 84” wide x 165" high.
  • VE-45 coating cannot exceed an 84" width.
  • RoomSide™ Low-E coating cannot exceed 60" wide x 142" high or 72" wide x 120" high.
  • ExtremEdge™ spacer cannot exceed 84" wide x 144" high.
  • Units with ExtremEdge™ cannot exceed 65 square feet.

 


 

Laminated Glass Sizes

70 sq ft
 

Configurations:

  • >50 square foot units must be heat treated.
  • Specialty laminates for hurricane applications have the following limitations:

– Saflex® Storm cannot exceed a 60" width or 144" height.

– StormGuard® cannot exceed a 72" width or 144" height.

– SentryGlas® cannot exceed a 72" width or 144" height.

– Level E - StormGuard® cannot exceed a 72" width or 120" height.

– Level E - SentryGlas® cannot exceed a 72" width or 120" height.

 

Components & Enhancements:

  • Ceramic frit silk-screen or spandrel units cannot exceed 84” wide x 165" high.
  • VE-45 coating cannot exceed an 84" width.
  • RoomSide™ Low-E coating cannot exceed 60" wide x 142" high or 72" wide x 120" high.
  • CyberShield™ units must be reviewed and approved by Viracon prior to receiving a quote:

– Requires a minimum 24" width.

– Cannot exceed 60" wide x 144" high or 72" wide x 120" high.

– CyberShield units cannot exceed 60 square feet.

 




Triangles

  • There must be a minimum of a 24" diagonal on all sizes.
  • One dimension can be less than 17", down to 12", as long as the other dimension is at least 21" (i.e., 12" x 21").
  • Right Triangles = 24" x 12" Block.
  • With triangles, one leg must always be at least 24" and the other leg cannot be less than 12".
  • Triangles should not exceed a 5:1 ratio.
  • Triangle Point Tolerance: Width measurement across must be at least 3/8". When designed with a 3/8" or less width across the point, the point may be broken off during manufacturing. This is considered within the tolerances up to the 3/8" width.
Triangle Charts

 

REQUEST SAMPLE

 


RESOURCES


 BIG GLASS BROCHURE

 BIG GLASS

 PATTERN REFERENCE GUIDE