BIG GLASS CONFIGURATIONS AVAILABLE UP TO 130” X 236”.

Glass sizing is based on 1/4" (6mm) to 3/8" (10mm) thickness for both interior and exterior lites in vertical applications.

 

Monolithic Glass Sizes

Monlithic Sizes

70 sq ft

 

Configurations:

  • >50 square foot units must be heat treated.

 

Components & Enhancements:

  • Ceramic frit silk-screen or spandrel units cannot exceed 84” wide x 165" high.
  •  


 

Insulating Glass Sizes

 
70 sq ft
 

 

Configurations:

  • >50 square foot units must be heat treated.

 

Components & Enhancements:

  • Ceramic frit silk-screen or spandrel units cannot exceed 84” wide x 165" high.
  • VE-45 coating cannot exceed an 84" width.
  • RoomSide™ Low-E coating cannot exceed 60" wide x 142" high or 72" wide x 120" high.
  • ExtremEdge™ spacer cannot exceed 84" wide x 144" high.
  • Units with ExtremEdge™ cannot exceed 65 square feet.
  • Offset insulating units with more than one long edge offset and staggered insulating units cannot exceed 140" high and cannot exceed 40 square feet.

 


 

Laminated Glass Sizes

70 sq ft
 

Configurations:

  • >50 square foot units must be heat treated.
  • Specialty laminates for hurricane applications have the following limitations:

– Saflex® Storm cannot exceed a 60" width or 144" height.

– StormGuard® cannot exceed a 72" width or 144" height.

– SentryGlas® cannot exceed a 72" width or 144" height.

– Level E - StormGuard® cannot exceed a 72" width or 120" height.

– Level E - SentryGlas® cannot exceed a 72" width or 120" height.

 

Components & Enhancements:

  • Ceramic frit silk-screen or spandrel units cannot exceed 84” wide x 165" high.
  • VE-45 coating cannot exceed an 84" width.
  • RoomSide™ Low-E coating cannot exceed 60" wide x 142" high or 72" wide x 120" high.
  • CyberShield™ units must be reviewed and approved by Viracon prior to receiving a quote:

– Requires a minimum 24" width.

– Cannot exceed 60" wide x 144" high or 72" wide x 120" high.

– CyberShield units cannot exceed 60 square feet.

 




Triangles

  • There must be a minimum of a 24" diagonal on all sizes.
  • One dimension can be less than 17", down to 12", as long as the other dimension is at least 21" (i.e., 12" x 21").
  • Right Triangles = 24" x 12" Block.
  • With triangles, one leg must always be at least 24" and the other leg cannot be less than 12".
  • Triangles should not exceed a 5:1 ratio.
  • Triangle Point Tolerance: Width measurement across must be at least 3/8". When designed with a 3/8" or less width across the point, the point may be broken off during manufacturing. This is considered within the tolerances up to the 3/8" width.
Triangle Charts

 