Sizes




CONFIGURATIONS
   - ClearPoint™
   - CyberShield™
   - Insulating
   - Laminated
   - Insulating Laminated
   - Laminated Insulating
   - Double Laminated Insulating
   - Monolithic
   - Triple Insulating

COMPONENTS
   - Coatings
   - Glass Substrates
   - Heat Treatment
   - Spacer
   - Silicone
   - Interlayer

ENHANCEMENTS
   - Argon
   - DigitalDistinctions™
   - Edgework
   - Holes
   - Notches
   - Silk-screen
   - Spandrel

PERFORMANCE
   - Solar
   - Acoustic

SIZES
   - BIG Glass

WARRANTIES

QUALITY

 

Now Available in BIG Glass Configurations.

Glass sizing is based on 1/4" (6mm) to 3/8" (10mm) thickness for both interior and exterior lites in vertical applications.

 

Monolithic Glass Sizes

 
 
70 sq ft
 

Configurations:

>50 square foot units must be heat treated.

 

Components & Enhancements:

Ceramic frit silk-screen or spandrel units cannot exceed an 84” width.

 

 

Insulating Glass Sizes

 
 
70 sq ft
 

 

Configurations:

>50 square foot units must be heat treated.

Laminated Insulating units with a coating on the #4 surface cannot exceed an 84" width or 

 

144" height for shipments through October 2017. This restriction is removed for shipments

 

beginning November 2017.

 

Components & Enhancements:

Ceramic frit silk-screen or spandrel units cannot exceed an 84" width.

VE-45 coating cannot exceed an 84" width.

RoomSide™ Low-E coating cannot exceed 60" wide x 142" high or 72" wide x 120" high.

ExtremEdge™ spacer cannot exceed 84" wide x 144" high.

Units with ExtremEdge™ cannot exceed 65 square feet.

ClearPoint™ units must be reviewed and approved by Viracon prior to receiving a quote:

 

– Requires a minimum 24" width.

 

– Cannot exceed a 72" width or 120" height when using a SentryGlas® interlayer.

 

– Cannot exceed an 84" width or 144" height when using a PVB interlayer.

 


 

Laminated Glass Sizes

 
 
70 sq ft
 

Configurations:

>50 square foot units must be heat treated.

Laminated Insulating units with a coating on the #4 surface cannot exceed an 84" width or 

 

144" height for shipments through October 2017. This restriction is removed for shipments

 

beginning November 2017.

Specialty laminates for hurricane applications have the following limitations:

 

– Saflex® Storm cannot exceed a 60" width or 144" height.

 

– StormGuard® cannot exceed a 72" width or 144" height.

 

– SentryGlas® cannot exceed a 72" width or 120" height.

 

– Level E - StormGuard® cannot exceed a 72" width or 120" height.

 

– Level E - SentryGlas® cannot exceed a 72" width or 120" height.

 

Components & Enhancements:

Ceramic frit silk-screen or spandrel units cannot exceed an 84" width.

VE-45 coating cannot exceed an 84" width.

RoomSide™ Low-E coating cannot exceed 60" wide x 142" high or 72" wide x 120" high.

ClearPoint™ units must be reviewed and approved by Viracon prior to receiving a quote:

 

– Requires a minimum 24" width.

 

– Cannot exceed a 72" width or 120" height when using a SentryGlas® interlayer.

 

– Cannot exceed an 84" width or 144" height when using a PVB interlayer.

CyberShield™ units must be reviewed and approved by Viracon prior to receiving a quote:

 

– Requires a minimum 24" width.

 

– Cannot exceed 60" wide x 144" high or 72" wide x 120" high.

 

– CyberShield units cannot exceed 60 square feet.

 

 




Triangles

  • There must be a minimum of a 24" diagonal on all sizes.
  • One dimension can be less than 17", down to 12", as long as the other dimension is at least 21" (i.e., 12" x 21").
  • Right Triangles = 24" x 12" Block.
  • With triangles, one leg must always be at least 24" and the other leg cannot be less than 12".
  • Triangles should not exceed a 5:1 ratio.
  • Triangle Point Tolerance - Width measurement across must be at least 3/8". When designed with a 3/8" or less width across the point, the point may be broken off during manufacturing. This is considered within the tolerances up to the 3/8" width.
Triangle Charts

 

REQUEST SAMPLE

 


RESOURCES


 BIG GLASS

 PATTERN REFERENCE GUIDE